Anyone know why Cisco doesn't allow for you to shut power down to a slot/module 
unless a FRU is installed in it? We can reproduce 100% multiple times in the 
lab WS-X6748-GE-TX installation's that causes the bus to stall 3 seconds. It 
has to do with the force you apply to the card during installation.

%C6KERRDETECT-SP-2-SWBUSSTALL: The switching bus is experiencing stall for 3 
seconds
%C6KERRDETECT-SP-2-SWBUSSTALL_RECOVERED: The switching bus stall is recovered 
and data traffic switching continues


Router(config)#no power enable module 8
%FRU Absent. Power admin state updated


Mark