It doesn't really matter whether you have powered off a slot or not (the module is recognized even when powered off). As soon as you oir the module, a bus stall will probably occur. We have seen that multiple times. Theoretically if you know how to insert/remove the module (not too quickly, not too slowly; it's a known pins "issue") you shouldn't have this problem, Personally, i always had 100% success when doing it myself, but i don't expect everyone else to be so lucky.

--
Tassos


Mark Mason wrote on 1/12/2011 23:52:
We also just labbed a VS-S720-10G running 122-33.SXJ1 and were able to shut a 
slot down without a module installed. Unfortunately we ALSO were able to 
incorrectly install a WS-X6748-GE-TX and cause the 3 second bus disruption. 
Anyone else run into this?

6509-v-e-test(config)#no power enable module 6
%FRU Absent. Power admin state updated
6509-v-e-test(config)#no power enable module 6
% slot is already disabled and not yet enabled
6509-v-e-test(config)#no power enable module 7
%FRU Absent. Power admin state updated
6509-v-e-test(config)#no power enable module 7
% slot is already disabled and not yet enabled
6509-v-e-test(config)#no power enable module 8
%FRU Absent. Power admin state updated
6509-v-e-test(config)#no power enable module 8
% slot is already disabled and not yet enabled
6509-v-e-test(config)#no power enable module 9
%FRU Absent. Power admin state updated
6509-v-e-test(config)#
6509-v-e-test(config)#no power enable module 9
% slot is already disabled and not yet enabled
6509-v-e-test(config)#
*Dec  1 21:14:36.304: %C6KPWR-SP-4-DISABLED: power to module in slot 8 set off 
(admin request)
6509-v-e-test(config)#
*Dec  1 21:15:07.123: %OIR-SP-6-REMCARD: Card removed from slot 8, interfaces 
disabled
*Dec  1 21:15:11.027: %C6KERRDETECT-SP-2-SWBUSSTALL: The switching bus is 
experiencing stall for 3 seconds
*Dec  1 21:15:16.063: %C6KERRDETECT-SP-2-SWBUSSTALL_RECOVERED: The switching 
bus stall is recovered and data traffic switching continues
*Dec  1 21:15:18.283: %C6KPWR-SP-4-DISABLED: power to module in slot 8 set off 
(admin request)


Mark

From: Mark Mason
Sent: Thursday, December 01, 2011 2:38 PM
To: '[email protected]'
Subject: Cisco 6k no power enable module

Anyone know why Cisco doesn't allow for you to shut power down to a slot/module 
unless a FRU is installed in it? We can reproduce 100% multiple times in the 
lab WS-X6748-GE-TX installation's that causes the bus to stall 3 seconds. It 
has to do with the force you apply to the card during installation.

%C6KERRDETECT-SP-2-SWBUSSTALL: The switching bus is experiencing stall for 3 
seconds
%C6KERRDETECT-SP-2-SWBUSSTALL_RECOVERED: The switching bus stall is recovered 
and data traffic switching continues


Router(config)#no power enable module 8
%FRU Absent. Power admin state updated


Mark

NOTICE: This electronic mail message and any files transmitted with it are 
intended
exclusively for the individual or entity to which it is addressed. The message,
together with any attachment, may contain confidential and/or privileged 
information.
Any unauthorized review, use, printing, saving, copying, disclosure or 
distribution
is strictly prohibited. If you have received this message in error, please
immediately advise the sender by reply email and delete all copies.
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to