On 01/12/2012 02:44 AM, Robert Hass wrote:
Hi

Is any way to have ERSPAN (on Cat6500) where traffic is copied only
for one IP within VLAN.
Eg. VLAN400, IP 2.2.2.2 (where VLAN consist /16 subnet and 2k active hosts)

Sadly not, on sup720.

Nexus 7k has this, and since it's using EARL8 as well I assume it's possible in hardware on sup2T, but as I recall no sign of the feature in software.

If it suits your needs, the "capture" SPAN type can apply an IP ACL in hardware:

mon sess X capture
  filter access-group ...

...but since it captures to a memory buffer, and you have to TFTP the packets off for any detailed analysis, this only works for relatively low-bandwidth captures.

No IPv6 either :o(

Also: beware of "capture" SPAN sessions. We've seen some bugs, which seem to have reared their head again in the SXJ train, where enabling a "capture" SPAN causes all existing and future ERSPAN sessions to malfunction - specifically, ERSPAN packet generation no longer obeys the routing table, and packets always flow to 0.0.0.0/0. This usually results in a routing loop...
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/