Hi,

On Sun, Jun 17, 2012 at 03:08:15AM -0500, Erik Sundberg wrote:
> The only other work around i can think of is to backhaul the need Switch 
> subinterface to a subinterface on our PE router then having a xcossover cable 
> between the two interfaces on our PE. But i am not a fan of this idea of 
> mine. So it would look like the following
> SWg1/2.3000----EoMPLS--PE1g0/0/0.10
> Xconnect cable between the GE interface on our PE1 or using the connect 
> command.
> SWg1/3.100----EoMPLS--PE1g0/0/1.10

Well, you can do *that* directly on the switch as well - have two ports as
"switchport mode access", one in vlan 100, the other one in vlan 3000,
and connect them via ethernet cross-over cable.

And then, of course, have g1/2 and g1/3 configured as trunk (or mux-uni), 
with vlan 3000/vlan 100 allowed.

gert
-- 
USENET is *not* the non-clickable part of WWW!
                                                           //www.muc.de/~gert/
Gert Doering - Munich, Germany                             [email protected]
fax: +49-89-35655025                        [email protected]

Attachment: pgpymKtSpzifB.pgp
Description: PGP signature

_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to