Hi,

On Tue, Aug 21, 2012 at 12:26:50PM +0000, John Brown wrote:
> Put a real optical power meter on the fibers and adjust with pads as
> needed to get your levels within specs.

That's *RX* power.  Not TX power.  TX power is something that is measured
inside the SFP - an the question "how can TX power go high" is a valid
one.

gert
-- 
USENET is *not* the non-clickable part of WWW!
                                                           //www.muc.de/~gert/
Gert Doering - Munich, Germany                             [email protected]
fax: +49-89-35655025                        [email protected]

Attachment: pgp0hXMbyGn4l.pgp