Fixed.

we got 2 other sfp's from another ME3600 in our network and put them in the (2) 
me3600's that were showing problems with those previous sfps, and they work 
fine.  apparently those other (3) SFP's we had were from a bad batch or 
something.

Aaron


-----Original Message-----
From: Pshem Kowalczyk [mailto:[email protected]] 
Sent: Friday, February 22, 2013 5:53 PM
To: Aaron
Cc: [email protected]
Subject: Re: [c-nsp] me3600x tengig sfp problem

Hi,


On 23 February 2013 06:08, Aaron <[email protected]> wrote:
> weird, look what happens...
>
>
>
> Feb 22 09:05:04: %PHY-4-SFP_NOT_SUPPORTED: The SFP in Te0/1 is not 
> supported Feb 22 09:05:04: %PM-4-ERR_DISABLE: gbic-invalid error 
> detected on Te0/1, putting Te0/1 in err-disable state Feb 22 09:05:04: 
> local_port_disable for: Te0/1 xcvr-disable failed
>

The fact that is has Cisco logo on it doesn't mean much these days, every 
platform and software version might have its own compatibility problems. Please 
check the list at the bottom of this document:
http://www.cisco.com/en/US/prod/collateral/switches/ps6568/ps10956/data_sheet_c78-601946.html
for the list of compatible optics.

kind regards
Pshem


_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to