You are not fully logged into the fabric. Did you create the necessary FCoE QoS policy?
Sent from handheld. On May 28, 2013, at 8:06 AM, "Piotr" <[email protected]> wrote: > Hi, > > I'm new in nexus world, i just test some switches and i have problem: > > There is one switch 5548 with version 6.0(2)N1(2a). I try to make fcoe > conenction between xenserver 6.1 (port 1/25) and linux fcoe target ( centos, > port 1/26). > > In both servers i have card: Cisco Systems Inc VIC FCoE HBA (rev a2), on > centos (target side) all looks good but from xenserver i don't see any > traffic. In xencenter i see the cisco card connected but when try to discover > new storage, xencenter don't find anything. > > > thanks for any help or clue > > regards, > Piotr > > > my config: > > vlan 11 > fcoe vsan 11 > > vsan database > vsan 11 > > interface vfc2 > bind interface Ethernet1/25 > no shutdown > > interface vfc26 > bind interface Ethernet1/26 > no shutdown > > vsan database > vsan 11 interface vfc2 > vsan 11 interface vfc26 > > > interface Ethernet1/25 > switchport mode trunk > spanning-tree port type edge trunk > > interface Ethernet1/26 > switchport mode trunk > spanning-tree port type edge trunk > > > > outputs: > > show lldp neighbors > Capability codes: > (R) Router, (B) Bridge, (T) Telephone, (C) DOCSIS Cable Device > (W) WLAN Access Point, (P) Repeater, (S) Station, (O) Other > Device ID Local Intf Hold-time Capability Port ID > 0018.8b9c.cfe6 mgmt0 120 g21 > nexus-2 Eth1/1 120 B Eth1/1 > nexus-2 Eth1/2 120 B Eth1/2 > nexus-2 Eth1/3 120 B Eth1/3 > nexus-2 Eth1/5 120 B Eth1/5 > nexus-test2 Eth1/7 120 B Eth1/1 > b0fa.eb72.7c06 Eth1/25 120 b0fa.eb72.7c0a > b0fa.eb72.7f3e Eth1/26 120 b0fa.eb72.7f42 > > > > show fcoe database > > ------------------------------------------------------------------------------- > INTERFACE FCID PORT NAME MAC ADDRESS > ------------------------------------------------------------------------------- > vfc26 0x6a0000 20:00:b0:fa:eb:72:7f:41 b0:fa:eb:72:7f:41 > > Total number of flogi count from FCoE devices = 1. > > VE Ports: > ------------------------------------------------------------------------------- > INTERFACE MAC ADDRESS VSAN > ------------------------------------------------------------------------------- > vfc1 54:7f:ee:8e:ad:0c 2 > > > > > > port 26, only target is ok: > > show flogi database > -------------------------------------------------------------------------------- > INTERFACE VSAN FCID PORT NAME NODE NAME > -------------------------------------------------------------------------------- > vfc26 2 0x6a0000 20:00:b0:fa:eb:72:7f:41 > 10:00:b0:fa:eb:72:7f:41 > > > but from xencenter side there is no traffic: > > show interface vfc 2 > vfc2 is trunking > Bound interface is Ethernet1/25 > Hardware is Ethernet > Port WWN is 20:01:54:7f:ee:8e:ac:7f > Admin port mode is F, trunk mode is on > snmp link state traps are enabled > Port mode is TF > Port vsan is 11 > Trunk vsans (admin allowed and active) (1-2,11) > Trunk vsans (up) () > Trunk vsans (isolated) () > Trunk vsans (initializing) (1-2,11) > 1 minute input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec > 1 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec > 0 frames input, 0 bytes > 0 discards, 0 errors > 0 frames output, 0 bytes > 0 discards, 0 errors > last clearing of "show interface" counters Sun Feb 21 11:15:15 2010 > > Interface last changed at Sun Feb 21 11:15:15 2010 > > > _______________________________________________ > cisco-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/cisco-nsp > archive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/