Thanks! I talked to our Cisco NCE about this and he gave me these commands:
show qos interface gigabitEthernet x/y- will show you 4 queues and also whether QoS is disabled or not sh int gi x/y counters detail -you will see packet counters in queue #1-4 incrementing Sh platform hardware interface g x/y stat | in TxB I'm nearly certain that this big buffer issue is the answer to my high variable latency problem, but there is still one mystery about this that has me completely perplexed. The high variable latency was only occurring in one direction (from VLAN A to VLAN B) but not in the other (from VLAN B to VLAN A). What really makes that weird is that because of some hsrp differences, we really had a circular topology for a bit. The path was *exactly* the same no matter which direction you were pinging. The ICMP packets had to travel around the same circle through the same devices and interfaces. So if we have big buffers on congested interfaces that are introducing variable latency, why would we only see it in one direction? When VLAN A pings VLAN B, it is the initial ICMP packet that would have been delayed, while the response would come in on a different interface that wasn't congested. When VLAN B pings VLAN A, the initial ping would not hit congested interfaces but the ping reply would. The total round trip time should have been similar, but it never was. I'm completely stumped by that. I even had Cisco HTTS on this for a couple of days and they couldn't figure it out. Thanks, John On Thu, Sep 26, 2013 at 1:50 AM, Terebizh, Evgeny <[email protected]> wrote: > Try also > "show platform hardware interface gigabitEthernet 1/1 tx-queue". > I guess it's gonna show the actual values for queue utilisation. > Please let me know if this helps. > > /ET > > > > > On 9/24/13 11:17 PM, "John Neiberger" <[email protected]> wrote: > > >I've been helping to troubleshoot an interesting problem with variable > >latency through a 4948. I haven't run into this before. I usually have > >seen > >really low latency through 4948s, but this particular application requires > >consistent low latency and they've been noticing that latency goes up on > >average as load goes up. It didn't seem to be a problem on their servers, > >but communication through busy interfaces seemed to dramatically increase > >the latency. They were used to <1ms latency and it was bouncing up to 20+ > >ms at times. I'm starting to think this is due to the shared output buffer > >in the 4948 causing the output buffer on the uplink to dynamically get > >bigger. > > > >I've been trying to find more details on how the 4948 handles its shared > >output queue space, but I haven't been able to find anything. Do any of > >you > >know more about how this works and what commands I could use to > >troubleshoot? I can't find anything that might show how much buffer space > >a > >particular interface is using at any given time, or if it even makes sense > >to think of it that way. If I knew the size of the buffer at any given > >moment, I could calculate the expected latency and prove whether or not > >that was the problem. > > > >Thanks! > >John > >_______________________________________________ > >cisco-nsp mailing list [email protected] > >https://puck.nether.net/mailman/listinfo/cisco-nsp > >archive at http://puck.nether.net/pipermail/cisco-nsp/ > > _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/