Before an upgrade to 15.3(3)S1a, a BFD session between a 9K and an ME3600 worked just fine. After the upgrade, BFD session wouldn't come up. I looked at the release notes and couldn't see any notes about behaviour changes in BFD or any specific caveats. BFD still works fine if the adjacent device is another ME3600 (only tested adjacent ME3600s that were *not* upgraded to 15.3(3)S1a).
I've got Cisco looking at it, but I'm just curious if anyone else has seen this change in behaviour. Previously, this ME3600 was running 15.3(3)S and it worked just fine to this same 9K (which is running XR 4.3.1). ! A9K ! router isis is-type level-2-only net 00.0720.1504.8009.0000.00 nsf cisco log adjacency changes log pdu drops address-family ipv4 unicast metric-style transition ! interface TenGigE0/0/0/6 bfd minimum-interval 300 bfd multiplier 3 bfd fast-detect ipv4 link-down fast-detect address-family ipv4 unicast ! ! ME3600 ! interface TenGigabitEthernet0/1 no switchport dampening mtu 9216 ip address 72.15.51.45 255.255.255.254 ip router isis 21949 logging event link-status carrier-delay msec 0 mpls ip bfd interval 300 min_rx 300 multiplier 3 isis bfd ! router isis 21949 net 00.0720.1505.0138.0000.00 is-type level-2-only metric-style transition spf-interval 5 1 50 prc-interval 5 1 50 lsp-gen-interval 5 1 50 bfd all-interfaces ! Thanks in advance. _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/