Hi,

On Wed, Mar 19, 2014 at 05:45:45PM +0100, Lukas Tribus wrote:
> >> should work fine. Manually set the interface media type on both sides to
> >> be rj-45, and make sure that the cable is a cross-over gigabit:
> > 
> > I wonder. Shouldn't this never be needed for Copper Gbit?
> 
> Its correct that GigabitEthernet mandates autoneg, and it is also correct
> that "mdix auto" REQUIRES autoneg, but afaik that doesn't mean all your
> gigabit/autoneg gear can also automatically do auto-mdix, because that
> probably requires different hardware (switching RX/TX).

There is nothing to "switch".  GigE on copper will use all 4 pairs *in both
directions at the same time*, unlike 10/100 (2 pairs, with one for RX only
and one for TX only).

There is something to negotiate - who is master, who is slave, and which
pair on side A goes to which pair on side B.

gert
-- 
USENET is *not* the non-clickable part of WWW!
                                                           //www.muc.de/~gert/
Gert Doering - Munich, Germany                             [email protected]
fax: +49-89-35655025                        [email protected]

Attachment: pgpUeMfEDmlWv.pgp
Description: PGP signature

_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to