On 10/15/2014 9:45 AM, Harry Hambi - Atos wrote:
Hi all,
Can someone help to explain the following error message :
Oct 15 14:39:14.024: %SFF8472-5-THRESHOLD_VIOLATION: Te2/0/1: Rx power high
warning; Operating value
: -1.8 dBm, Threshold value: -2.0 dBm.
Does the message suggest a faulty optic?. Thanks in advance.
That message is saying that your optical receive level is too high for
that optic. If you are running a long reach optic over a short
distance, that will happen. You can either swap out for shorter
distance optics, or you can use an optical attenuator to reduce the
signal on the receiver side.
Jeremy "TheBrez" Bresley
[email protected]
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp