So this threshold is programed in the 10GBase -SR module, you cannot change this?, is this correct?. The module is a cisco SR, is this a known with cisco optics?.
Rgds Harry Harry Hambi BEng(Hons) MIET Rsgb -----Original Message----- From: Marian Ďurkovič [mailto:[email protected]] Sent: 15 October 2014 18:32 To: Harry Hambi - Atos; '[email protected]' Subject: Re: [c-nsp] Optics Standard 10GBase-SR modules should have RX High Warning threshold programmed to -1.0 dBm, so your receive power -1.8 dBm is fully OK. Your modules seem to have the threshold incorrectly programmed to -2.0 dBm, which causes the error. M. On Wed, 15 Oct 2014 14:45:08 +0000, Harry Hambi - Atos wrote > Hi all, > Can someone help to explain the following error message : > > Oct 15 14:39:14.024: %SFF8472-5-THRESHOLD_VIOLATION: Te2/0/1: Rx power > high warning; Operating value : -1.8 dBm, Threshold value: -2.0 dBm. > Does the message suggest a faulty optic?. Thanks in advance. _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/