Yes you can put it all in one domain if you'd like. Rather large domain IMHO, but is possible depending on how your topology is laid out. There is a finite limit of how many devices can be cascaded.
When they speak of region they're talking about MST region. With MST you need to have the configuration 100% the same or else it's considered a different region. MST scales more because of less processes running on the hardware. On Thu, Jan 15, 2015 at 3:04 AM, Hansen, Ulrich Vestergaard (WP TE R&D MSD SWS SCS SHW) <[email protected]> wrote: > Hi > > Quick question, hope someone can chip in. > > We're currently struggling with RPVST+ hitting the max number of instances > on a branch with 3750X switches (128 instances). > Considering MST as an alternative, as the logical topology is anyway the > same for all 128 instances. > > Reading some papers, Cisco recommends that you place as many switches as > possible into a single region ( > http://www.cisco.com/c/en/us/support/docs/lan-switching/spanning-tree-protocol/24248-147.html) > but fails to mention how it actually scales. Can I add 200 access switches > to one MST domain? 300? 400? > > Best regards > Ulrich > > > > > _______________________________________________ > cisco-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/cisco-nsp > archive at http://puck.nether.net/pipermail/cisco-nsp/ > _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/