> Victor Sudakov
> Sent: Saturday, January 23, 2016 7:06 AM
>
> Dear Colleagues,
>
> There is an IP MPLS network with MTU=1600 on all routers' interfaces.
> There are plans to add some backup Ethernet links whose maximum frame
> size cannot exceed 1500 (hardware limit).
>
> Is there any way those links can be put to any good use in the MPLS
> network?
>
> Thanks in advance for any input.
>
Dear Victor,
If you are using MPLS routers that perform forwarding in SW you can test in the
lab if they would be able to handle the fragmentation so during the failure of
primary link they would have to fragment.
Otherwise the fragmentation would have to be done on CE routers which is
something that some customers might not be happy about.
adam
Adam Vitkovsky
IP Engineer
T: 0333 006 5936
E: [email protected]
W: www.gamma.co.uk
This is an email from Gamma Telecom Ltd, trading as “Gamma”. The contents of
this email are confidential to the ordinary user of the email address to which
it was addressed. This email is not intended to create any legal relationship.
No one else may place any reliance upon it, or copy or forward all or any of it
in any form (unless otherwise notified). If you receive this email in error,
please accept our apologies, we would be obliged if you would telephone our
postmaster on +44 (0) 808 178 9652 or email [email protected]
Gamma Telecom Limited, a company incorporated in England and Wales, with
limited liability, with registered number 04340834, and whose registered office
is at 5 Fleet Place London EC4M 7RD and whose principal place of business is at
Kings House, Kings Road West, Newbury, Berkshire, RG14 5BY.
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/