Jerry,

The first thing that hit me is "64K circuit" and "TSU".   Is this a T1 or a
DDS circuit?  TSU's won't work on a DDS line, only on T1's.

Rodgers Moore, CCDP, CCNP-Security

"Jerry Deer" <[EMAIL PROTECTED]> wrote in message
CC7FDD694D1DD31189F30008C79185EC015F9424@EXCHANGE">news:CC7FDD694D1DD31189F30008C79185EC015F9424@EXCHANGE...
> I have a 64k point to point ckt running from point A to Point B with
Adtran
> tsu on each end connected to the telco's dmarc with a straight through
> cable. I have alarm lights on both tsu's. both are properly configured as
> our other tsu's are. here is the puzzling part the telco says they can
test
> good to THEIR dmarc at both points A and B but cannot see our tsu's on
> either side. I have tested both of the straight through cables that go
from
> the telco dmarc to the tsu and both are good.
> any suggestions would be greatly appreciated!
> thanks,
> JD
>
> ___________________________________
> UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
> FAQ, list archives, and subscription info: http://www.groupstudy.com
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
> ---


___________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to