>>>> Firesox 7/18/03 6:03:15 AM >>> >Folks, >I am troubleshooting the 3524XL and get the following message at the boot. > >C3500XL POST FAILURE: front-end post: GigabitEthernet0/2: > >C3500XL POST FAILURE: looped-back packet not received > >It is connected to 2950G-24. 2950 is seeing the 3524XL via CDP, but not >vice versa. > >Has anyone seen this error messgae/condition? > >Thanks in advance. >
http://www.cisco.com/warp/public/473/164.html#topicsub1 It appears that your 3500XL has faulty hardware on that interface. If this is a new switch you need to return it with an RMA, or you can get a replacement if you have it under contract. HTH, John Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=72572&t=72563 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]