interfaces send a keepalive-type loopback packet every x no of seconds to
verify the interface's integrity. same thing happens at POST.
The message means faulty Hardware. More specifically, it is probably the Rx
of your interface that has failed.
Solution=Hardware replacement.
-Nakul

""Firesox""  wrote in message
news:[EMAIL PROTECTED]
> Folks,
> I am troubleshooting the 3524XL and get the following message at the boot.
>
> C3500XL POST FAILURE: front-end post: GigabitEthernet0/2:
>
> C3500XL POST FAILURE: looped-back packet not received
>
>
>
> It is connected to 2950G-24.  2950 is seeing the 3524XL via CDP, but not
> vice versa.
>
>
>
> Has anyone seen this error messgae/condition?
>
>
>
> Thanks in advance.




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=72696&t=72563
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]