from the console type "switch console", this will make the Supervisor
console the console for the MSFC, then do a normal recovery (send break,
load an IOS, etc)
hth
Andy
----- Original Message -----
From: Amit Lilani <[EMAIL PROTECTED]>
Newsgroups: groupstudy.cisco
To: <[EMAIL PROTECTED]>
Sent: Friday, August 18, 2000 6:44 PM
Subject: urgent 6509 msfc down.
> hi guys,
>
> i have a 6509 switch with 2 sup 1's and 2 msfc's ( modules 15 and 16)
> what went wrong was we upgraded the msfc module with the wrong ios code
> (12.07.XE1). no it does not seem to come up and goes into a loop. still i
> can go into RMON using the switch console command. put whenever i use
xmodem
> to upgrade the ios it FAILS... its gives the message timeout.... and say
> automatic logout... i spoke to cisco tac... (very slow in responding back)
> they mailed me back saying the baud rate can not go more that 9600 on a
> console which is true......I DONT know how to proceeds ...any
> clues...suggestions are most welcome....
>
> thanks a lot for all your help
>
> amit.
>
>
> ___________________________________
> UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
> FAQ, list archives, and subscription info: http://www.groupstudy.com
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
>
___________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com