Hmm. I have a CS500 as well.
Looking at my config and comparing to the info you have provided, I have
some suggestions. Note that you may have already done this - as I cant see
ur config or every command you've entered.
1. Are you using (ex.)'telnet 1.1.1.1 2001' to rev telnet to the 0 line?
Note that the CS500 ports are from labeled 0-15 where as their corresponding
tty lines are 1-16.
2. Cabling problem? If you are connecting to a 2500 series, you will only
need a std rollover cable between the two.
3. Use 'stopbits 1' for your tty lines. Default is not 1, 1.5 I think?
Probably wont help the immediate problem though...
-Brad
[EMAIL PROTECTED]
----- Original Message -----
From:
To:
Sent: Saturday, April 28, 2001 8:47 PM
Subject: 500-CS...HELP!! [7:2414]
> Ok GUYS n GALS,
> I got a simple dilemma, but I can't seem to get the solution. I know its
> staring me in the face! :) I bought a 500-CS off ebay and I config with
> TRANS IN ALL, but it doesn't take so I use TRANS IN TELNET and TRANS OUT
> TELNET on the console of my test router and on the async line I have the
> cable plugged to and use IP ADD 1.1.1.1 255.255.255.255 as a loopback int.
> When I try a Reverse Telnet, it opens, but I get a blank screen and NO
> CURSOR
> for my router? WHAT GIVES?
> Thanks,
> Rob H.
> FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=2419&t=2414
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html