THANKS!
-----Original Message-----
From: Brad Ellis
Sent: Mon 11/26/2001 2:18 PM
To: Pierre-Alex J. Guanel
Cc:
Subject: Re: Slimline 2 [7:27365]
Pierre,
Hi! You have the wrong switch type configured for the Simline2.
You want:
ISDN switch-type basic-net3
Also, this switch type does NOT use spids! FYI
thanks,
-Brad Ellis
CCIE#5796 (R&S / Security)
Network Learning Inc
[EMAIL PROTECTED]
used Cisco gear: www.optsys.net
CCIE Labs, racks, and classes:
http://www.ccbootcamp.com/quicklinks.html
""Pierre-Alex J. Guanel"" wrote in
message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> I am using the Slimline 2 ISDN simulator from PDS
technologies.
>
> I cannot get the SPID to be accepted. (See below)
>
>
> ISDN BRI0 interface
> dsl 0, interface ISDN Switchtype = basic-5ess
> Layer 1 Status:
> ACTIVE
> Layer 2 Status:
> TEI = 64, Ces = 1, SAPI = 0, State =
MULTIPLE_FRAME_ESTABLISHE
> TEI 64, ces = 1, state = 4(await init)
> spid1 configured, no LDN, spid1 sent, spid1 NOT
valid
>
> I have not modifed the default phone numbers 1111 and 2222
configured on
> Slimline
>
> Below are my configs for bri0
> interface BRI0
> ip address 10.0.0.1 255.255.255.0
> encapsulation ppp
> no ip route-cache
> no ip mroute-cache
> dialer map ip 10.0.0.2 1111
> dialer-group 1
> isdn switch-type basic-5ess
> isdn spid1 2222
>
> Is there a default LDN number I have to configure?
>