Thanks guys. Tried the TERA TERM program and it works. Why do I even use
HyperTerm?

""Georg Pauwen""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Hi Kevin,
>
> this is from the Cisco site:
>
> Console Port Problem on Cisco 2500
>
> Symptom
> Output from the router on the console screen can be seen, but anything
which
> is typed in is not seen.
>
> Problem
> The terminal is set to use Ready To Send/Clear To Send (RTS/CTS) flow
> control.
>
> On all other routers, the console port is wired to connect RTS and CTS so
> even though we don't do real flow control, the terminal sees CTS in
response
> to asserting RTS.
>
> Due to the RJ45 -> DB25 adapter wiring for the 2500, this is not possible.
>
> Solution
> Disable hardware flowcontrol or strap CTS high.
>
> Hope this helps,
>
> Georg