I have configured a few Flexwans with ATM and frame relay and they work quite well. If you have redundant sup/MSFC's I would recommend running SRM as opposed the config-sync on the MSFC's.
Dave Tim Potier wrote: > > I have a choice here, and am not sure of the load probs. Core can be a 6509 > with 2 MSFC 2's/SUPII's, with an uplink to a 7206 with an OC-3 ATM PA > (MM).......OR, eliminate the 7206, get a Flexwan module for the 6509 and use > the same OC-3 ATM PA. > > LAN side looks like this: > 12 remote wiring closets, each having a 4006 with 4 48-port 10/100. Uplinks > to 6509 via 1000SX GBICs (trunking). Mixed IP/IPX environment. 17 VLANS > (IP and IPX), so the MSFC2's will be doing the inter-vlan routing. Route > IPX on LAN with RIPv2, IPX on WAN with EIGRP. IP on WAN is OSPF.--> no > choice here. > > WAN traffic mainly TN3270, web traffic and IPX (replication), plus OSPF > routing updates. > > Suggestions? About a 11K savings on the non-7206 design. > > Thanks -- David Madland Sr. Network Engineer CCIE# 2016 Qwest Communications Int. Inc. [EMAIL PROTECTED] 612-664-3367 "Emotion should reflect reason not guide it" Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=41959&t=41904 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]