The interface may say up up but if you can't get any traffic across
it... your just spoofing the interface.  Do a show frame-relay pvc, is
your PVC active.  You also appear to be missing part of the show serial
output, where is your LMI sent and received???

ROUTER>sh frame-rela pvc

PVC Statistics for interface Serial5/0 (Frame Relay DTE)

              Active     Inactive      Deleted       Static
  Local          4            0            0            0
  Switched       0            0            0            0
  Unused         0            0            0            0

DLCI = 16, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE =
Serial5/0.16

  input pkts 9579930       output pkts 9799989      in bytes 3594749594
  out bytes 3653765588     dropped pkts 114         in FECN pkts 0
  in BECN pkts 0           out FECN pkts 0          out BECN pkts 0
  in DE pkts 2             out DE pkts 0
  out bcast pkts 9729374    out bcast bytes 3647281854
  pvc create time 17w0d, last time pvc status changed 17w0d

mid-7206-b>sh int s5/0
Serial5/0 is up, line protocol is up
  Hardware is M4T
  Description: ROUTER
  MTU 1500 bytes, BW 2048 Kbit, DLY 20000 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation FRAME-RELAY IETF, crc 16, loopback not set
  Keepalive set (10 sec)
  LMI enq sent  1032897, LMI stat recvd 1032903, LMI upd recvd 0, DTE
LMI up
  LMI enq recvd 0, LMI stat sent  0, LMI upd sent  0
  LMI DLCI 1023  LMI type is CISCO  frame relay DTE

  Dave


Naafi Matovu wrote:
> 
> Hi all
> 
> I've been configuring a cisco 2600 dual wic with three subinterfaces on
> serial 0/1.
> If i leave the the keepalive to 10 sec, the line protocol on the serial 0/1
> keeps coming up but going down after a couple of seconds. The only way i
can
> keep the line protocol up is (no keepalive) on seial 0/1. Iam not sure
> whether this is the best way of sorting out this problem.Here is the
current
> config on this serial port
> 
> Serial0/1 is up, line protocol is up
> Hardware is PowerQUICC Serial
> MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec,
> reliability 255/255, txload 1/255, rxload 1/255
> Encapsulation FRAME-RELAY IETF, loopback not set
> Keepalive not set
> Broadcast queue 0/64, broadcasts sent/dropped 96/227, interface broadcasts
> 96
> Last input 00:00:17, output 00:00:12, output hang never
> Last clearing of "show interface" counters 01:26:53
> Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
> Queueing strategy: weighted fair
> Output queue: 0/1000/64/0 (size/max total/threshold/drops)
> Conversations 0/2/256 (active/max active/max total)
> Reserved Conversations 0/0 (allocated/max allocated)
> 5 minute input rate 0 bits/sec, 0 packets/sec
> 5 minute output rate 0 bits/sec, 0 packets/sec
> 11467 packets input, 876671 bytes, 0 no buffer
> Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
> 33 input errors, 0 CRC, 33 frame, 0 overrun, 0 ignored, 0 abort
> 11125 packets output, 799491 bytes, 0 underruns
> 0 output errors, 0 collisions, 45 interface resets
> 0 output buffer failures, 0 output buffers swapped out
> 2 carrier transitions
> DCD=up DSR=up DTR=up RTS=up CTS=up
-- 
David Madland
Sr. Network Engineer
CCIE# 2016
Qwest Communications Int. Inc.
[EMAIL PROTECTED]
612-664-3367

"Emotion should reflect reason not guide it"




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=42364&t=42350
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to