We have two 3640s that we use for dial-up access.... very nice for that
purpose.... we have coming in to one of them 2 PRIs, then 48 MICA digital
modems... it rocks....  you can dial-in with ISDN BRI for ether 64 or
128Kbps (bonded) or handle analog dial-ins... The other has a single PRI
(only 18 DS0s active) with 18 MICA modems in it along with two T1s back to
our main office.....

They work... they don't have problems.... 95% of the few dial-up related
problems are usually a password/authentication issues that are mostly caused
by the user anyway.....   The beauty of the 3640 or 3660 over the 2600s is
sheer volume....  you can plug alot of stuff into 6 slots, making it a very
versatile mid-level box...

Mike W.

"Kazan, Naim"  wrote in message
news:[EMAIL PROTECTED]...
> The 2600 series will work well with your requirement. just build to your
> specs.




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=50996&t=50951
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]