Hi Franck,

It can be – although it’s worth noting that we don’t authenticate requests to 
Homer in Project Clearwater. Any client able to send traffic to port 7888 of a 
Homer node may perform any operation on any data stored in Homer, without 
providing any authentication; allowing external access therefore presents a 
significant security risk. Please see 
https://github.com/Metaswitch/crest/blob/dev/docs/homer_features.md for more 
details

Ellie

From: Clearwater [mailto:[email protected]] On 
Behalf Of Franck Malka
Sent: 10 January 2016 15:44
To: [email protected]
Subject: [Clearwater] Can homer interface can be set to SSL or TLS?

Can homer interface can be set to SSL or TLS?
Meaning for the Ut interface.

Franck Malka

[cid:[email protected]]<http://www.facebook.com/modulocs>[cid:[email protected]]<http://www.twitter.com/modulocs>[cid:[email protected]]<http://www.linkedin.com/company/modulo-communications-systems-ltd.>



Mobile   +972 54 488 9090<tel:%2B972%2054%20488%209090>
Tel        +972 72 274 4002<tel:%2B972%2072%20274%204002>
Fax       +972   3 774 1114<tel:%2B972%C2%A0%C2%A0%203%20774%201114>
Skype   franck.malka



http://www.modulo.co.il/
14 Imber St. Kyriat Arie,
PO Box 4098,
Petah Tikva 49514

[cid:[email protected]]



[cid:[email protected]]
NOTE: The contents of this email and any attachments are confidential. They are 
intended for the named recipient(s) only. If you have received this email in 
error, please notify the system manager or the sender immediately and do not 
disclose the contents to anyone or make copies thereof.



_______________________________________________
Clearwater mailing list
[email protected]
http://lists.projectclearwater.org/mailman/listinfo/clearwater_lists.projectclearwater.org

Reply via email to