Hi Asra,

This looks like an issue we resolved in a recent release, where the default SIP 
URIs didn’t include ports and needed an SRV lookup 
(https://github.com/Metaswitch/sprout/commit/d25f334063e7e344254faa65d0de2eb90fc1399d).
 If you take the most recent all-in-one node, or the one we’ll release later 
this week, that should fix this problem.

If you can’t do that, adding the line “192.168.0.4 scscf.cw-aio” to /etc/hosts, 
and editing /etc/clearwater/shared_config to set 
‘scscf_uri=”sip:scscf.cw-aio:5054;lr;transport=tcp”’ might solve this.

Best,
Rob

From: Asra Baneamoon [mailto:[email protected]]
Sent: 18 April 2016 17:14
To: 
[email protected]<mailto:[email protected]>
Subject: error message

 Dear All;

 i have install clearwater All-in-one image on Linux 14.0 on Cloudwatt of 
Orange.
my problem even i have two registerd sip agent on Zioper (PC and Cellphone) but 
 i have not reached yet to make a call
the  error message is Sip 408 timeout request
on bono_current.txt  error messge is "Failed to retrive record for 
-sip.-tcpscscf.192.168.0.4 :Domain na$"
if you have any information  about this, Could you please share it with  me.

Best Regards


_______________________________________________
Clearwater mailing list
[email protected]
http://lists.projectclearwater.org/mailman/listinfo/clearwater_lists.projectclearwater.org

Reply via email to