Hi Asra, This looks like an issue we resolved in a recent release, where the default SIP URIs didn’t include ports and needed an SRV lookup (https://github.com/Metaswitch/sprout/commit/d25f334063e7e344254faa65d0de2eb90fc1399d). If you take the most recent all-in-one node, or the one we’ll release later this week, that should fix this problem.
If you can’t do that, adding the line “192.168.0.4 scscf.cw-aio” to /etc/hosts, and editing /etc/clearwater/shared_config to set ‘scscf_uri=”sip:scscf.cw-aio:5054;lr;transport=tcp”’ might solve this. Best, Rob From: Asra Baneamoon [mailto:[email protected]] Sent: 18 April 2016 17:14 To: [email protected]<mailto:[email protected]> Subject: error message Dear All; i have install clearwater All-in-one image on Linux 14.0 on Cloudwatt of Orange. my problem even i have two registerd sip agent on Zioper (PC and Cellphone) but i have not reached yet to make a call the error message is Sip 408 timeout request on bono_current.txt error messge is "Failed to retrive record for -sip.-tcpscscf.192.168.0.4 :Domain na$" if you have any information about this, Could you please share it with me. Best Regards
_______________________________________________ Clearwater mailing list [email protected] http://lists.projectclearwater.org/mailman/listinfo/clearwater_lists.projectclearwater.org