Maybe a clever little script that parses the /proc/mdsats file periodically and 
fires off an email if it doesn't like what it sees?

J

---
Jon Watson
1.403.875.6048

----- Original Message -----
From: [EMAIL PROTECTED] <[EMAIL PROTECTED]>
To: CLUG General <[email protected]>
Sent: Mon Jul 30 15:56:18 2007
Subject: Re: [clug-talk] Hardware raid monitoring?

On 7/30/07, Martin Glazer <[EMAIL PROTECTED]> wrote:
> Hey,
>
> I'm running a server with an Intel hardware raid controller using 4 SATA
> drives (raid 5 + hotspare). It is using the megaraid driver.
>
> Is there any way to monitor the health of the raid - I would like
> notification (email, syslog) if the raid gets degraded?
>
> I did a test by pulling one of the drives - the machine started beeping
> like crazy, but there was absolutely nothing in my syslog files or even
> in dmesg. This is concerning if nobody is near the machine and so
> doesn't hear the beeping...

I think smartmontools would help out there (smartd)

I don't know if they have support for Intel RAID (what chip is it?)

In your case, smartd should send you an email if something as drastic
as a disk disappearing occurred, regardless of smartd's raid
controller support.

-Mark

_______________________________________________
clug-talk mailing list
[email protected]
http://clug.ca/mailman/listinfo/clug-talk_clug.ca
Mailing List Guidelines (http://clug.ca/ml_guidelines.php)
**Please remove these lines when replying
_______________________________________________
clug-talk mailing list
[email protected]
http://clug.ca/mailman/listinfo/clug-talk_clug.ca
Mailing List Guidelines (http://clug.ca/ml_guidelines.php)
**Please remove these lines when replying