I suspect Hobart is not telling us the whole truth about his experiments.
In particular we might be held in the dark as to which other operands he is
using on the REXX variable access stages.

/*
/*
Signal on novalue
pipe='rexxvars|take 1|console'
Address COMMAND
'PIPE' pipe
'RITA' pipe
Exit RC

Gets me this response (as it should):

s CMS COMMAND TR EXEC A1 TR
CMS
s CMS COMMAND TR EXEC A1 TR
CMS
    CPU Utilization by Pipeline Specification          29 May 2008
20:35:34


     0.099 (     0.099) ms total in "NoName001" (1
invocation)


     2.015 ms
total.


Detailed output from Rita in UNNAMED RITA007.

Adding MAIN to the rexxvar stage gets the same response (as it should).

Yes, RITA does run a REXX filter to process the output of RUNPIPE.  And yes,
if you go out of your way you might be able to interfere with it, though I
cannot think of how to do so off the top of my head.


   j.

2008/5/29 SPITZ, HOBART CTR DFAS <[EMAIL PROTECTED]>:

> That's exactly what it sounds like, but, per p.3 of "Streamlining Your
> Pipes", we are using RITA MODULE.  (I don't think we actually had a
> choice.  :-)   )
>
> We use a configuration variable PIPE that we set to RITA when we want to
> get performance info., so we know that the programs haven't changed.
> Our pipe statements look like:
>
>        Pipe "(listerr end ? name" UsedName"."ExecType"."LineNo()")",
> ...
>
> A number of programs all show the same problem.  Since these programs
> sub-filters all receive and set the callers variables correctly when
> PIPE is "pipe", and not when it's "rita", it would seem to be something
> external to the programs.
>
> Any ideas?
>
> - Hobart
>
> -----Original Message-----
> From: CMSTSO Pipelines Discussion List
> [mailto:[EMAIL PROTECTED] On Behalf Of Rob van der Heij
> Sent: Wednesday, May 28, 2008 5:14 PM
> To: [email protected]
> Subject: Re: [CMS-PIPELINES] FW: Rita+*VAR*+CALLPIPE
>
> On Wed, May 28, 2008 at 4:08 PM, SPITZ, HOBART CTR DFAS
> <[EMAIL PROTECTED]> wrote:
>
> > When we run RITA and we have a filter, any *VAR* stages (REXXVARS,
> VAR,
> > VARLOAD, VARSET, etc.), in a CALLPIPE, seem to not be able to get the
> > variables that they get when we run without RITA.
> >
> > Are we doing something wrong?
>
> Could it be you have a PIPE or RITA EXEC involved. That would
> introduce another level of execcomm and mess up things.
>
> Rob
>

Reply via email to