John,

Valid range are 8000-87BF and 660A-660F
The rest does not exist

Ready; T=0.02/0.03 13:41:59
cp trace diag 8 run cmd d psw g
Ready; T=0.01/0.01 13:42:25
pipe cp q da details 8000-8FFF 660A !> a a a
 -> 0180BACE  EX       44001000     01855FB8  DIAG    83240008    00000008
PSW = 03EC1000 8180BAD2
GPR  0 =  0183F447  01855FB8  3F997F00  3F997FF0
GPR  4 =  00000000  0008EE5D  3F99AAA8  3F99D078
GPR  8 =  3F9888F8  3F99AC50  BF988F04  3F997E38
GPR 12 =  8180BAA0  3F997EA8  97899788  0180BA9E
 -> 0180BACE  EX       44001000     01855FB8  DIAG    83240008    00000008
PSW = 03EC0000 8180BAD2
GPR  0 =  000121CC  01855FB8  3F997F00  3F8DF1A0
GPR  4 =  00000028  00090CFE  3F99AAA8  3F99D078
GPR  8 =  3F9888F8  3F99AC50  BF988F04  3F997E38
GPR 12 =  8180BAA0  3F997EA8  97899788  0180BA9E
Ready(00040); T=0.01/0.26 13:42:56
sp cons close
 -> 00F1E59C  DIAG    83130008    00000008


Ready; T=0.01/0.02 13:46:27
q 660A-660B
DASD 660A CP SYSTEM 630WV2   140
DASD 660B XX660B
Ready; T=0.01/0.01 13:46:34
q 8FF0-8FFF
HCPQDV1003E 8FF0-8FFF was not found.
Ready(01003); T=0.01/0.01 13:47:01
q 87BF
DASD 87BF XX67BF
Ready; T=0.01/0.01 13:47:11




Le 02/07/2015 12:39, « CMS/TSO Pipelines Discussion List on behalf of John
P. Hartmann » <[email protected] on behalf of
[email protected]> a écrit :

>Alain, have you got devices 8FFF, 660A and 660B?
>
>Please do
>
>CP TRACE DIAG 8 RUN CMD D PSW G
>
>while running the failing pipeline.
>
>On 06/30/2015 04:06 PM, Alain Benveniste wrote:
>> Hi,
>>
>> If i do a q da details 8000-8FFF 660A through CP I get the result, with
>> a PIPE CP ...... !> a a a, 660A does not appear in the result, the same
>> with 660A-660A instead. With 660A-660B it works.
>>
>> Regards
>> Alain
>>

Reply via email to