John, Valid range are 8000-87BF and 660A-660F The rest does not exist
Ready; T=0.02/0.03 13:41:59 cp trace diag 8 run cmd d psw g Ready; T=0.01/0.01 13:42:25 pipe cp q da details 8000-8FFF 660A !> a a a -> 0180BACE EX 44001000 01855FB8 DIAG 83240008 00000008 PSW = 03EC1000 8180BAD2 GPR 0 = 0183F447 01855FB8 3F997F00 3F997FF0 GPR 4 = 00000000 0008EE5D 3F99AAA8 3F99D078 GPR 8 = 3F9888F8 3F99AC50 BF988F04 3F997E38 GPR 12 = 8180BAA0 3F997EA8 97899788 0180BA9E -> 0180BACE EX 44001000 01855FB8 DIAG 83240008 00000008 PSW = 03EC0000 8180BAD2 GPR 0 = 000121CC 01855FB8 3F997F00 3F8DF1A0 GPR 4 = 00000028 00090CFE 3F99AAA8 3F99D078 GPR 8 = 3F9888F8 3F99AC50 BF988F04 3F997E38 GPR 12 = 8180BAA0 3F997EA8 97899788 0180BA9E Ready(00040); T=0.01/0.26 13:42:56 sp cons close -> 00F1E59C DIAG 83130008 00000008 Ready; T=0.01/0.02 13:46:27 q 660A-660B DASD 660A CP SYSTEM 630WV2 140 DASD 660B XX660B Ready; T=0.01/0.01 13:46:34 q 8FF0-8FFF HCPQDV1003E 8FF0-8FFF was not found. Ready(01003); T=0.01/0.01 13:47:01 q 87BF DASD 87BF XX67BF Ready; T=0.01/0.01 13:47:11 Le 02/07/2015 12:39, « CMS/TSO Pipelines Discussion List on behalf of John P. Hartmann » <[email protected] on behalf of [email protected]> a écrit : >Alain, have you got devices 8FFF, 660A and 660B? > >Please do > >CP TRACE DIAG 8 RUN CMD D PSW G > >while running the failing pipeline. > >On 06/30/2015 04:06 PM, Alain Benveniste wrote: >> Hi, >> >> If i do a q da details 8000-8FFF 660A through CP I get the result, with >> a PIPE CP ...... !> a a a, 660A does not appear in the result, the same >> with 660A-660A instead. With 660A-660B it works. >> >> Regards >> Alain >>