On 14 February 2016 at 06:55, Paul Gilmartin <[email protected]> wrote:

>
> At least I think that's what's happening.  If I set the loop limit smaller
> the problem does not occur.  Is there a way to flush the buffers and
> recover
> the storage without exiting my Rexx stage?
>
> Do I need to nest another Rexx stage?
>
> pipe query
> PIPINX086I CMS/TSO Pipelines, 5654-030/5655-A17 1.0112
> (Version.Release/Mod) - Generated 30 Jul 2015 at 16:26:54.
>
>
At first glance I would assume the added pipeline to wrap up when you sever
the output. It will notice end-of-file on its primary input and wrap up
business. Unless your schematic display excludes things in the pipeline
that keep him alive. Maybe the dispatcher does not get to running those
pipes to termination because your REXX stage keeps running - try a SUSPEND
after you SEVER the output. You might run one of the addpipes list LISTRC
to see when it terminates.

Sir Rob the Plumber

Reply via email to