"pipe literal Test Line|browse" works fine here, Dale, on z/VM 6.4. What
service level are you at?

DJ
---
DAVID JONES | MANAGING DIRECTOR FOR ZSYSTEMS SERVICES | z/VM, Linux, and
Cloud
703.237.7370 (Office) | 281.578.7544 (CELL)

INFORMATION TECHNOLOGY COMPANY [1]

On 08.28.2018 11:15 AM, Dale R. Smith wrote:

> We finally got around to installing z/VM 6.4 with the new level of PIPELINEs 
> available with CMS 28.  I had some Execs that were using the BROWSE stage to 
> display some Help information for the Exec.  This works fine with the Marist 
> Distribution, (what we have been using for years), but fails with the new 
> PIPEs in CMS 28:  (Screen displays OK, pressing Enter or PFKey and I  get 
> this)
> FPLIOS292E I/O error on CONSOLE; CSW X'000015D0 0020FFFF', CCW X'2AD2DFF0 
> 2080FFFF'
> FPLMSG004I ... Issued from stage 10 of pipeline 1 name "FPLRICBW"
> FPLMSG001I ... Running "fullscr"
> SCRCTL001E Unexpected return code 12 from the pipeline..
> FPLMSG004I ... Issued from stage 9 of pipeline 1 name "FPLRICBW"
> FPLMSG001I ... Running "brwctrl % 27 132 1 1 1 1 F1 697 1047 ? 0-00-r1-02"
> Ready(00292);
>
> At first I thought it might be related to the size of the data being 
> displayed or the size of the screen, but even this simple PIPE fails with the 
> same error:  pipe literal Test Line|browse


Links:
------
[1] http://www.itconline.com/