#539: Product-scope TracAdmin commands don't take effect until tracd is 
restarted
------------------------+-------------------------------
  Reporter:  rjollos    |      Owner:  olemis
      Type:  defect     |     Status:  accepted
  Priority:  major      |  Milestone:  Release 8
 Component:  dashboard  |    Version:
Resolution:             |   Keywords:  tracadmin command
------------------------+-------------------------------

Comment (by olemis):

 I have attached two patches introducing each a global for basic
 synchronization of product configuration instances and related test cases
 . Details :

 {{{#!sh

 $ hg qapplied
 t539/t539_r1516428_test_product_config_sync.diff
 t539/t539_r1516428_product_config_sync.diff

 $ hg log -r qparent
 changeset:   398:17cd489fc827
 tag:         qparent
 tag:         svn-1516428
 user:        matevz@13f79535-47bb-0310-9956-ffa450edef68
 date:        Thu Aug 22 12:17:32 2013 +0000
 summary:     #444 - Show number of attachments next to attachment heading

 }}}

 After applying both patches the unit tests for configuration objects all
 succeed. I'm running the whole unit and functional test suites and report
 here the results I got shortly after .

-- 
Ticket URL: <https://issues.apache.org/bloodhound/ticket/539#comment:7>