nielifeng commented on issue #9702:
URL: https://github.com/apache/seatunnel/issues/9702#issuecomment-5140897942

   I traced this against SeaTunnel 2.3.11 and the current `dev` branch. 
`DefineSinkType` itself is present in 2.3.11 (introduced by #9114), and the 
distribution includes it in `seatunnel-transforms-v2.jar`.
   
   The failure is caused by the 2.3.11 Flink launcher packaging runtime 
dependencies relative to the current working directory. Your command runs 
`../bin/start-seatunnel-flink-15-connector-v2.sh` from another directory, so 
the old script can miss `connectors/lib/plugins` and submit a runtime without 
`seatunnel-transforms-v2.jar`. Factory discovery then reports `DefineSinkType` 
as not found.
   
   This has been fixed on `dev` by #10419 (merge commit `35840fd603`): the 
Flink 1.3/1.5+/2.0 launchers now resolve those directories under `APP_DIR` and 
always write `runtime.tar.gz` under the SeaTunnel installation directory.
   
   For 2.3.11, the workaround is to run the launcher from `$SEATUNNEL_HOME` and 
regenerate `$SEATUNNEL_HOME/runtime.tar.gz`, then confirm it contains the 
`connectors/seatunnel-transforms-v2` JAR. Upgrading to a release containing 
#10419 is the permanent fix.
   
   No additional PR is needed for current `dev`.


-- 