On Thu 16 March 2017 22:31:33 joerg Reisenweber wrote: > For a way more > thorough test, the charger circuit in TWL4030 should get switched off prior > to
Yet another approach (maybe the smartest): make sure BBCHEN (charge enable) is *NOT* getting set during boot. During test, makes sure BBCHEN has been 0 to start with, set BBSEL=11, enable BBCHEN and instantly start logging the delta-v/delta-t for the next maybe 5 or 10s. The curve tells all you want to know about state and health of bupbat polyacene cap. /j -- () ascii ribbon campaign /\ against html e-mail - against proprietary attachments http://www.georgedillon.com/web/html_email_is_evil.shtml http://www.nonhtmlmail.org/campaign.html http://www.georgedillon.com/web/html_email_is_evil_still.shtml http://www.gerstbach.at/2004/ascii/ (German)