On Mon, 25 Nov 2013, Phil Dibowitz wrote:

> OK run-down of testing:
>
> 885:
>  config dump: OK
>  config update: OK
>  firmware update: OK
> 895:
>  config dump: OK
>  config update: OK
>  firmware update: failed - see [1]
> 1100:
>  config dump: OK
>  config update: OK
>  firmware update: can't test

I did a bunch of testing on my fleet of remotes, too:

688:
   config dump: OK
   config update: OK
   firmware update: OK
890:
   config dump: OK
   config update: OK
300:
   config dump: OK [1]
   config update: OK
200:
   config dump: OK [1]
   config update: OK

[1] No status provided while config being read.  Patch forthcoming.

Everything worked, but we are not providing any status while reading the 
config on MH.  I think I probably never noticed this because I'm always 
running in debug mode and seeing the printf's fly by.  Since the user 
doesn't really have any idea what's going on, we should probably fix it. 
I'll work on a patch.

------------------------------------------------------------------------------