Hi,

On Mon, 2014-11-10 at 20:21 -0500, [email protected] wrote:
>     I'm working on a user interface for Connman and I've found that
> whenever  I register a counter using the Manager interface that the
> system logs   start filling up with messages such as this: 
> 
> Nov 10 19:59:33 antec connmand[401]: enp4s0 {RX} 5453 packets 3993018 bytes 
> Nov 10 19:59:33 antec connmand[401]: enp4s0 {TX} 5792 packets 1060010 bytes 
> Nov 10 19:59:33 antec connmand[401]: enp4s0 {newlink} index 2 address  
> 00:1C:C0:27:B8:A1 mtu 1500 
> Nov 10 19:59:33 antec connmand[401]: enp4s0 {newlink} index 2 operstate  6 
> <UP> 
> Nov 10 19:59:33 antec connmand[401]: wlan0 {newlink} index 3 address  
> 00:18:39:06:A4:54 mtu 1500 
> Nov 10 19:59:33 antec connmand[401]: wlan0 {newlink} index 3 operstate 2  
> <DOWN> 
> 
> They seem to come in groups every time the counter updates.  The
> counter  itself works just fine.  I have two questions. 
> 
> 1) Is this the expected behavior when a counter is registered. 

Currently there debug messages are there in the code, so yes.

> 2) If yes is there anyway I can turn it off. 

Send a patch to remove said logging?

Cheers,

        Patrik

_______________________________________________
connman mailing list
[email protected]
https://lists.connman.net/mailman/listinfo/connman

Reply via email to