Please DO NOT REPLY to this mail or send email to the developers
about this bug. Please follow-up to Bugzilla using this link:
http://bugs.contribs.org/show_bug.cgi?id=9200
Have you checked the Frequently Asked Questions (FAQ)?
http://wiki.contribs.org/SME_Server:Documentation:FAQ
Please also take the time to read the following useful guide:
http://www.chiark.greenend.org.uk/~sgtatham/bugs.html
==================================================================
Bug ID: 9200
Summary: Interface traffic graph broken
Classification: Contribs
Product: SME Contribs
Version: 9.1
Hardware: ---
OS: ---
Status: UNCONFIRMED
Severity: normal
Priority: P3
Component: smeserver-sysmon
Assignee: [email protected]
Reporter: [email protected]
QA Contact: [email protected]
System monitor shows no data for the Ethernet Traffic graph.
After some checking I believe that this is due to the version of sysstat
installed (9.0.4) which reports traffic statistics in kB/s, whereas the old
sysstat as installed in SME 8.2 (I believe version 7.0.2) was reporting values
in byt/s.
Therefore, when parsing the output of /usr/bin/sadf, the sysmon daemon finds no
valid values.
Affected packages/versions:
smeserver-sysmon-6.4-4.el6.sme.noarch
sysstat-9.0.4-27.el6.i686
SME version 9.1
--
You are receiving this mail because:
You are the QA Contact for the bug._______________________________________________
Mail for each SME Contribs bug report
To unsubscribe, e-mail [email protected]
Searchable archive at http://lists.contribs.org/mailman/public/contribteam/