Dear Jan,

Jan Dohnalek wrote:
Contacts to atoms of n+1 (n-1) residue are not being generated automatically

This is a feature.  These contacts are removed for clarity.

and also the "feature" of non-clickable sym related atoms (with no contact distances displayed) seems to be still there. Or are these fixed in a recent version?

That is not a feature - it is a bug. However, I have not been able to reproduce it. If you could give me a pdb accession code and a region of space where symmetry contacts cannot be labeled, I would be very interested. I have not worked on this code for more than a year, so I doubt that the new versions are fixed.

Paul.

Reply via email to