-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

Hi Bernhard,

this sounds odd - wouldn't both maps be calculated from F/PHI by coot
itself? Why would Paul (Kevin?) make a difference there between phenix
and refmac5?

Curiously,
Tim

On 01/17/2013 10:23 AM, Bernhard Lohkamp wrote:
> Hi Pedro,
> 
> this is due to the map sampling (which seems different between the
> two programs). Anyway, for now you can change the weighting
> manually:
> 
> Extensions->Refinement->Set Density Fit Graph Weight
> 
> B
> 
> On 17/01/2013 10:11, Pedro M. Matias wrote:
>> Hi,
>> 
>> I encountered a strange problem while running the "Density Fit
>> Analysis" widget on a structure refined with PHENIX. All residues
>> are represented with a red bar (see picture) with low CC.
>> 
>> Using the same input coordinate and MTZ file in REFMAC produces
>> normal "Density Fit Analysis" graphs (see picture).
>> 
>> I am at a loss to understand why this is happening...
>> 
>> This happens with both 0.6.2 and 0.7 versions of Coot.
>> 
>> Best regards,
>> 
>> Pedro.
>> 
>> 
>> Industry and Medicine Applied Crystallography Macromolecular
>> Crystallography Unit ___________________________________ Phones :
>> (351-21) 446-9100 Ext. 1669 (351-21) 446-9669 (direct) Fax   :
>> (351-21) 441-1277 or 443-3644
>> 
>> email : mat...@itqb.unl.pt
>> 
>> http://www.itqb.unl.pt/research/biological-chemistry/industry-and-medicine-applied-crystallography
>>
>>
>>
>> 
http://www.itqb.unl.pt/labs/macromolecular-crystallography-unit
>> 
>> Mailing address : Instituto de Tecnologia Quimica e Biologica 
>> Apartado 127 2781-901 OEIRAS Portugal
> 

- -- 
- --
Dr Tim Gruene
Institut fuer anorganische Chemie
Tammannstr. 4
D-37077 Goettingen

GPG Key ID = A46BEE1A

-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.12 (GNU/Linux)
Comment: Using GnuPG with Mozilla - http://enigmail.mozdev.org/

iD8DBQFQ98yxUxlJ7aRr7hoRAk6dAJ40C/NnDzSq5qwUge8smqs12jvolACeJzP+
x8dEGDrJzHvkVekddgcvPgs=
=aZ9b
-----END PGP SIGNATURE-----