I see the same thing with Autobuster structures.

-----Original Message-----
From: Mailing list for users of COOT Crystallographic Software 
[mailto:[email protected]] On Behalf Of Pedro M. Matias
Sent: Thursday, January 17, 2013 6:16 AM
To: [email protected]
Subject: Re: Problem with Coot Density Fit Analysis with PHENIX map coefficients

Hi, Bernhard,

To clarify my previous e-mail, in both cases the maps are being 
calculated from weighted coefficients from an MTZ file output by the program.
I tried calculating a weighted 2Fo-Fc map in CCP4i using the PHENIX 
MTZ file and the end-result (red bars) was the same.

Pedro.

At 09:23 17-01-2013, Bernhard Lohkamp wrote:
>Hi Pedro,
>
>this is due to the map sampling (which seems different between the 
>two programs). Anyway, for now you can change the weighting manually:
>
>Extensions->Refinement->Set Density Fit Graph Weight
>
>B
>
>On 17/01/2013 10:11, Pedro M. Matias wrote:
>>Hi,
>>
>>I encountered a strange problem while running the "Density Fit Analysis"
>>widget on a structure refined with PHENIX. All residues are represented
>>with a red bar (see picture) with low CC.
>>
>>Using the same input coordinate and MTZ file in REFMAC produces normal
>>"Density Fit Analysis" graphs (see picture).
>>
>>I am at a loss to understand why this is happening...
>>
>>This happens with both 0.6.2 and 0.7 versions of Coot.
>>
>>Best regards,
>>
>>Pedro.
>>
>>
>>Industry and Medicine Applied Crystallography
>>Macromolecular Crystallography Unit
>>___________________________________
>>Phones : (351-21) 446-9100 Ext. 1669
>>                (351-21) 446-9669 (direct)
>>      Fax   : (351-21) 441-1277 or 443-3644
>>
>>email : [email protected]
>>
>>http://www.itqb.unl.pt/research/biological-chemistry/industry-and-medicine-applied-crystallography
>>
>>http://www.itqb.unl.pt/labs/macromolecular-crystallography-unit
>>
>>Mailing address :
>>Instituto de Tecnologia Quimica e Biologica
>>Apartado 127
>>2781-901 OEIRAS
>>Portugal
>
>--
>***************************************************
>
>Dr. Bernhard Lohkamp
>Assistant Professor
>Div. Molecular Structural Biology
>Dept. of Medical Biochemistry and Biophysics (MBB)
>Karolinska Institutet
>S-17177 Stockholm
>Sweden
>
>phone: (+46) 08-52487651
>fax:   (+46) 08-327626
>email: [email protected]

Industry and Medicine Applied Crystallography
Macromolecular Crystallography Unit
___________________________________
Phones : (351-21) 446-9100 Ext. 1669
               (351-21) 446-9669 (direct)
     Fax   : (351-21) 441-1277 or 443-3644

email : [email protected]

http://www.itqb.unl.pt/research/biological-chemistry/industry-and-medicine-applied-crystallography
http://www.itqb.unl.pt/labs/macromolecular-crystallography-unit

Mailing address :
Instituto de Tecnologia Quimica e Biologica
Apartado 127
2781-901 OEIRAS
Portugal                                
Notice:  This e-mail message, together with any attachments, contains
information of Merck & Co., Inc. (One Merck Drive, Whitehouse Station,
New Jersey, USA 08889), and/or its affiliates Direct contact information
for affiliates is available at 
http://www.merck.com/contact/contacts.html) that may be confidential,
proprietary copyrighted and/or legally privileged. It is intended solely
for the use of the individual or entity named on this message. If you are
not the intended recipient, and have received this message in error,
please notify us immediately by reply e-mail and then delete it from 
your system.

Reply via email to