On 07/04/2019 14:02, Ahmad Khalifa wrote:


I'm working with a lattice made of a tubulin monomer that I modeled and refined 
in Coot.

Sounds fine.


I have fitted other units of the monomer along the length and to the side of my monomer in a cryo-EM map to study tubulin interactions with non tubulin proteins.

OK, that's what I would do.


My problem: sometimes I have to refine and change the rotamers in multiple 
tubulin monomers

OK, don't do that.

Let's say you have A,B,C,D,E chains. Make C your "reference chain" - make all the changes to that and then propagate the changes to the other chains via an NCS operation. Set the Draw Ghosts master chain to C then, whenever you like NCS -> Copy NCS master to others.

and it's very hard to keep track of all these changes in different units.

Yes I can imagine that.

Regards,

Paul.

########################################################################

To unsubscribe from the COOT list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=COOT&A=1

Reply via email to