On Tue, 22 Aug 2023 18:21:17 GMT, Weibing Xiao <[email protected]> wrote:
>> Please refer to JDK-8314063.
>>
>> The failure scenario is due to the setting of connection timeout. It is
>> either too small or not an optimal value for the system. When the client
>> tries to connect to the server with LDAPs protocol. It requires the
>> handshake after the socket is created and connected, but it fails due to
>> connection timeout and leaves the socket open. It is not closed properly due
>> to the exception handling in the JDK code.
>>
>> The change is adding a try/catch block and closing the socket in the catch
>> block, and the format of the code got changed consequently.
>
> Weibing Xiao has updated the pull request incrementally with one additional
> commit since the last revision:
>
> format the code
Such a restriction appears to be a flaw in the design of SocketFactory and its
use in jndi ldap.
Consider the existing updated code and the inference of your assertion:
```
// create the socket
if (connectTimeout > 0) {
InetSocketAddress endpoint =
createInetSocketAddress(host, port);
// unconnected socket
socket = factory.createSocket();
// connected socket
socket.connect(endpoint, connectTimeout);
if (debug) {
System.err.println("Connection: creating socket with " +
"a timeout using supplied socket factory");
}
} else {
// continue (but ignore connectTimeout)
if (socket == null) {
// connected socket
socket = factory.createSocket(host, port);
if (debug) {
System.err.println("Connection: creating socket using " +
"supplied socket factory");
}
}
}``
Your assertion is, "If the custom factory does not implement the method
creatSocket (no method parameters), it will fail for creating the socket."
Thus, the first block of the, if (connectTimeout > 0) condition, is
problematic. This assumes that if the timeout is > 0, then the factory will
implement the no args factory method createSocket(). BUT that means that an
implementor of a customer factory would need to have knowledge of the internal
implemntation of this class, and ensure no args factory method createSocket is
implemented. If an implementor has knowledge to implement the no args factory
method when timeout > 0, then they can also have knowldge to implement the no
args factory method when the timeout is 0 or < 0, as suggested by the
restructure.
Additionally, this would not prohibit a restructure of the non factory
createConnectionSocket.
-------------