Ron, That sounds ok. I copied over dbm690t in both the mainboard and target directories to advantech/som-5781. I will be getting things to work in those directories. Should I submit a non-working patch to get things started?
The som-5781 is com-express so the SuperIO lives on the baseboard. The developer baseboard that I am using has an ITE chip on it whereas the release board will have a Winbond. I don't see any way to select at configuration time which SuperIO/Baseboard is connected. Would it make sense to implement a standard SuperIO interface and just link against the one we want? Would there be a need to support multiple SuperIO in the same system? Has there been any steps taken towards doing this? Any interest other than myself? The release baseboard is a custom embedded design so it doesn't really make sense to have a directory for it. Thoughts on how to handle this? Thanks Dan Lykowski --- On Wed, 12/31/08, ron minnich <[email protected]> wrote: > From: ron minnich <[email protected]> > Subject: Re: [coreboot] 690/600 Just starting out. > To: "Bao, Zheng" <[email protected]> > Cc: [email protected], [email protected] > Date: Wednesday, December 31, 2008, 12:32 AM > On Tue, Dec 30, 2008 at 6:20 PM, Bao, Zheng > <[email protected]> wrote: > > The dbm690t uses S1G1 socket. The > mainboard/amd/xxx/Config.lb should be > > modified to AM2. > > > > That's fine for testing but, Dan, if that test works > let's get a > mainboard directory set up for your new board the > "right" way. > > Thanks > > ron > > -- > coreboot mailing list: [email protected] > http://www.coreboot.org/mailman/listinfo/coreboot -- coreboot mailing list: [email protected] http://www.coreboot.org/mailman/listinfo/coreboot