I'm trying to put Cosign on server 2012R2 for the first time, and I'm hitting a fatal issue right out of the gate. As soon as the module is registered, IIS no longer works as the app pool dies as soon as it tries to service a http request. I have not even configured a site to use cosign yet, so the appearance is the module is not compatible with IIS 8.5?
Steps taken: Download 3.1.1 zip for IIS7 from http://cosign.sourceforge.net/download.shtml Copy the src/Cosign_Schema.xml file into C:\Windows\System32\inetsrv\config\schema Copy the x64 CosignModule.dll file into C:\Windows\System32\inetsrv Open an administrative command prompt and change directory to c:\windows\system32\inetsrv. Enter this command: appcmd install module /name:"Cosign" /image:"%windir%\system32\inetsrv\CosignModule.dll" At that point, the expectation is that the webserver just keeps working as it has been as Cosign isn't even involved yet. Unfortunately, as I said the app pool dies because cosign causes a fatal issue. From the Event Viewer: Application: The Module name Cosign path C:\Windows\system32\inetsrv\CosignModule.dll returned an error from registration. The data is the error. System: Application pool 'DefaultAppPool' is being automatically disabled due to a series of failures in the process(es) serving that application pool. Not real helpful other than confirming what was obvious, Cosign is killing the app pool so the server is dead until the module is removed. I noted some things changed in the instructions, so I then added the x86 .dll to SysWOW64\inetsrv, uinstalled the module, and reinstalled with appcmd install module /name:"Cosign" /image:"CosignModule.dll" Unfortunately this made no change, the app pool still dies as soon as a page request is made over http. Is it really supposed to be the case the x64 module goes in the 32bit directory and vice versa? Why is the module causing the app pool to crash out before it's even active in a configuration? Thanks! Yadin -- ------------------------------------------------------------------- Yadin Flammer - Systems Administrator College of Arts& Architecture, Penn State University 220 Borland Building Office Phone: 814-865-0990 University Park, PA 16802 Help Desk: 814-865-AAIT Email: y...@psu.edu Dept. Fax: 814-863-6227 ------------------------------------------------------------------------------ _______________________________________________ Cosign-discuss mailing list Cosign-discuss@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/cosign-discuss