Hi, 

My intranet server (currently running Apache, DHCP and Squid) seems to be 
ill. Its SCSI disks are doing fine but I'm always receiving these errors 
into my logs : 


Dec  8 04:24:54 intranet kernel: scsi0: ERROR on channel 0, id 3, lun 0, 
CDB: Write (10) 00 00 23 ee 7f 00 00 10 00 
Dec  8 04:24:54 intranet kernel: Info fld=0x23ee7f, Current sd08:31: sense 
key Medium Error 
Dec  8 04:24:54 intranet kernel: Additional sense indicates Address mark not 
found for id field 
Dec  8 04:24:54 intranet kernel:  I/O error: dev 08:31, sector 2354752 
Dec  8 09:02:34 intranet kernel: Info fld=0x203807, Current sd08:31: sense 
key Recovered Error 
Dec  8 09:02:34 intranet kernel: Additional sense indicates Address mark not 
found for id field 
Dec  8 09:50:35 intranet kernel: Info fld=0x203857, Current sd08:31: sense 
key Recovered Error 
Dec  8 09:50:35 intranet kernel: Additional sense indicates Address mark not 
found for id field 
Dec  8 10:22:37 intranet kernel: Info fld=0x203897, Current sd08:31: sense 
key Recovered Error 
Dec  8 10:22:37 intranet kernel: Additional sense indicates Address mark not 
found for id field 
Dec  8 20:59:03 intranet kernel: Info fld=0x2035ef, Current sd08:31: sense 
key Recovered Error 
Dec  8 20:59:03 intranet kernel: Additional sense indicates Address mark not 
found for id field 
Dec  8 22:07:06 intranet kernel: Info fld=0x203667, Current sd08:31: sense 
key Recovered Error 
Dec  8 22:07:06 intranet kernel: Additional sense indicates Id CRC or ECC 
error 


Dec  9 04:04:24 intranet kernel: Info fld=0x2378ff, Current sd08:31: sense 
key Recovered Error 
Dec  9 04:04:24 intranet kernel: Additional sense indicates Address mark not 
found for id field 
Dec  9 06:29:29 intranet kernel: scsi0: ERROR on channel 0, id 3, lun 0, 
CDB: Write (10) 00 00 23 77 a7 00 00 10 00 
Dec  9 06:29:29 intranet kernel: Info fld=0x2377a7, Current sd08:31: sense 
key Medium Error 
Dec  9 06:29:29 intranet kernel: Additional sense indicates Address mark not 
found for id field 
Dec  9 06:29:29 intranet kernel:  I/O error: dev 08:31, sector 2324328 


Does this means I'll need to change my disks ? I have been googling for info 
on this topic and all information I found told me that it's a hardware 
problem. 

However, the same problem were happening on SCSI device id 2 (another SCSI 
disk on the same SCSI controller) and then I switched my /var partition from 
the previous id 2 disk and put it in another disk, the one which is now in 
id 3 and the same error is happening. 

Does this means my SCSI controller can be the one at fault ? Any ideas ? 

-- 
++----------------------------------------------------------------------++ 
||  Andre Luis Lopes                   [EMAIL PROTECTED]               || 
||  Debian-BR Project                  http://debian-br.cipsga.org.br   || 
||  Public GPG KeyID                   9D1B82F6                         || 
||  Keyserver                          wwwkeys.eu.pgp.net               || 

_________________________________________________________
Voce quer um iGMail protegido contra v�rus e spams? 
Clique aqui: http://www.igmailseguro.ig.com.br


-- 
To UNSUBSCRIBE, email to [EMAIL PROTECTED]
with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]