On Tue, Dec 10, 2002 at 11:03:25AM -0200, Andr� Lu�s Lopes wrote:
> Dec  8 04:24:54 intranet kernel: Info fld=0x23ee7f, Current sd08:31: sense 
> key Medium Error 
...
> Dec  9 06:29:29 intranet kernel:  I/O error: dev 08:31, sector 2324328 

For me those always were a sign of badblocks. If it's just one scsi disk
or you can remove one raid disk a time, run "badblocks" over each disk
to find the faulty (each disk that is behind /dev/sdb because 08:31 is
/dev/sdb15).

bye,

-christian-

-- 
Christian Hammers    WESTEND GmbH - Aachen und Dueren     Tel 0241/701333-0
[EMAIL PROTECTED]     Internet & Security for Professionals    Fax 0241/911879
          WESTEND ist CISCO Systems Partner - Authorized Reseller


-- 
To UNSUBSCRIBE, email to [EMAIL PROTECTED]
with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]

Reply via email to