Hi there
On Mon, 26 Oct 2026, Rob van der Putten wrote:
A little update:
I still haven't been able to replicate this problem in any other way than
hookup up the DCF77 receiver to the multi serial card.
However, using Minicom to send ASCII data (which just works) and then hooking
up the DCF77 receiver, shows ASCII when there should only be binary data. As
if old data from a buffer is being flushed.
I noticed a change in /usr/src/linux/drivers/tty/serial/8250/8250_port.c;
/*
* Recover from no-data-ready and FIFO error condition to avoid getting
* stuck in the ISR.
*/
if (!(status & UART_LSR_DR) && (status & UART_LSR_FIFOE))
serial8250_clear_and_reinit_fifos(up);
Flushing the FIFO when this really should happen would probably result in the
experienced behaviour. It is perfectly normal for a DCF77 receiver to produce
a continuous stream of breaks, framing- and parity errors and the software
should just ignore these.
I will try to build a kernel without this change. I haven't build a kernel
since the 1990's, so this may take some time to figure out.
If this works I will try to modify the above change.
Removing this change does indeed solve my problem.
Modifying the above change to ignore parity errors also works;
if (!(status & UART_LSR_DR) && (status & UART_LSR_FIFOE) && \
!(status & UART_LSR_PE))
serial8250_clear_and_reinit_fifos(up);
Regards,
Rob