Hi all, I have a disk which gives me the following smart output. The stopped self-test is my bad.
What do you guys think? I would tend to say the drive is OK, but 16 errors is a tad too much, imo. Thanks, Richard PS: If the extended test comes up with anything bad, I will throw it away, anyway. ================================= smartctl version 5.37 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate NL35 family Device Model: ST3400832NS Serial Number: 3NF1CJFP Firmware Version: 5.01 User Capacity: 400,087,375,360 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Tue Apr 14 22:07:47 2009 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 247) Self-test routine in progress... 70% of test remaining. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 134) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 064 049 006 Pre-fail Always - 170828508 3 Spin_Up_Time 0x0003 098 097 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 5 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 074 060 030 Pre-fail Always - 29283841 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 440 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 19 194 Temperature_Celsius 0x0022 046 049 000 Old_age Always - 46 (Lifetime Min/Max 0/21) 195 Hardware_ECC_Recovered 0x001a 064 048 000 Old_age Always - 170828508 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 16 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 16 occurred at disk power-on lifetime: 20 hours (0 days + 20 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 10 51 01 6e 88 93 ee Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 37 ff 01 6e 88 93 ee 00 00:02:58.685 SET MAX ADDRESS EXT 27 ff 00 6e 88 93 e0 00 00:02:58.684 READ NATIVE MAX ADDRESS EXT 37 ff 00 6e 88 93 ee 00 00:02:58.656 SET MAX ADDRESS EXT 27 ff 01 6e 88 93 e0 00 00:03:08.046 READ NATIVE MAX ADDRESS EXT 37 ff 01 6e 88 93 ee 00 00:03:08.046 SET MAX ADDRESS EXT Error 15 occurred at disk power-on lifetime: 20 hours (0 days + 20 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 10 51 01 6e 88 93 ee Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 37 ff 01 6e 88 93 ee 00 00:02:58.685 SET MAX ADDRESS EXT 27 ff 00 6e 88 93 e0 00 00:02:58.684 READ NATIVE MAX ADDRESS EXT 37 ff 00 6e 88 93 ee 00 00:02:58.656 SET MAX ADDRESS EXT 27 ff 01 af 90 93 e0 00 00:02:58.656 READ NATIVE MAX ADDRESS EXT 29 00 01 af 90 93 e0 00 00:02:58.209 READ MULTIPLE EXT Error 14 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 10 51 01 6e 88 93 ee Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 37 ff 01 6e 88 93 ee 00 00:47:38.007 SET MAX ADDRESS EXT 27 ff 00 6e 88 93 e0 00 00:47:37.979 READ NATIVE MAX ADDRESS EXT 37 ff 00 6e 88 93 ee 00 00:47:47.368 SET MAX ADDRESS EXT 27 ff 01 6e 88 93 e0 00 00:47:47.368 READ NATIVE MAX ADDRESS EXT 37 ff 01 6e 88 93 ee 00 00:47:47.242 SET MAX ADDRESS EXT Error 13 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 10 51 01 6e 88 93 ee Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 37 ff 01 6e 88 93 ee 00 00:47:38.007 SET MAX ADDRESS EXT 27 ff 00 6e 88 93 e0 00 00:47:37.979 READ NATIVE MAX ADDRESS EXT 37 ff 00 6e 88 93 ee 00 00:47:37.979 SET MAX ADDRESS EXT 27 ff 01 af 90 93 e0 00 00:47:37.532 READ NATIVE MAX ADDRESS EXT 29 00 01 af 90 93 e0 00 00:47:37.532 READ MULTIPLE EXT Error 12 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 10 51 01 6e 88 93 ee Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 37 ff 01 6e 88 93 ee 00 00:44:40.973 SET MAX ADDRESS EXT 27 ff 00 6e 88 93 e0 00 00:44:40.847 READ NATIVE MAX ADDRESS EXT 37 ff 00 6e 88 93 ee 00 00:44:40.847 SET MAX ADDRESS EXT 27 ff 01 6e 88 93 e0 00 00:44:40.700 READ NATIVE MAX ADDRESS EXT 37 ff 01 6e 88 93 ee 00 00:44:40.698 SET MAX ADDRESS EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Aborted by host 90% 439 - # 2 Extended offline Self-test routine in progress 70% 440 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. -- To UNSUBSCRIBE, email to debian-user-requ...@lists.debian.org with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org