https://issues.apache.org/jira/browse/DERBY-4345?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=12754010#action_12754010
]
Lily Wei commented on DERBY-4345:
---------------------------------
Hmm... This is very strange. I just run it with trunk (revision 813232).
management.InactiveManagementMBeanTest pass for me.
$ java junit.textui.TestRunner org.apache.derbyTesting.functionTests.tests.mana
gement.InactiveManagementMBeanTest
..
Time: 5.521
OK (2 tests)
Looking from the dump, it is waiting for thread to finish. I did not change
anything in DRDAConnThread.java. I will keep looking. Will this be different
SDK issue?
> Inconsistent behavior regarding shutting down embedded engine from
> ClientDataSource and ClientDriver/DriverManager
> ------------------------------------------------------------------------------------------------------------------
>
> Key: DERBY-4345
> URL: https://issues.apache.org/jira/browse/DERBY-4345
> Project: Derby
> Issue Type: Bug
> Components: Network Server
> Affects Versions: 10.5.1.1
> Environment: Windows Vista with JDK 1.6
> Reporter: Lily Wei
> Priority: Minor
> Attachments: DERBY-4345-2.diff, DERBY-4345.diff,
> javacore.20090908.140353.4296.0001.txt, ReproDerby3532.java,
> ReproDerby4345.java
>
>
> When investigate DERBY-3532, Kathey and I found inconsistent behavior in turn
> of connection modes possible to shut down the engine underneath the network
> server. Currently, users can shutdown from the client remotely with
> ClientDataSource but not with ClientDriver/DriverManager. The two should be
> the same.
> Should we disable the capability for ClientDataSource or enable it for
> ClientDriver? I am leaning toward to disable the capability for
> ClientDataSource. However, I am not sure about the risk of functionality
> disable impact for existing production customers.
--
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.