We are not parsing for 100G speed correctly.
With this patch we should be able to configure 100G link.

Fixes 710d3bd5568d: ("net/bnxt: add 100G speed detection")
Cc: sta...@dpdk.org
Signed-off-by: Ajit Khaparde <ajit.khapa...@broadcom.com>
---
 drivers/net/bnxt/bnxt_hwrm.c | 8 +++++++-
 1 file changed, 7 insertions(+), 1 deletion(-)

diff --git a/drivers/net/bnxt/bnxt_hwrm.c b/drivers/net/bnxt/bnxt_hwrm.c
index 5450a0253..4dcdf36a5 100644
--- a/drivers/net/bnxt/bnxt_hwrm.c
+++ b/drivers/net/bnxt/bnxt_hwrm.c
@@ -2042,6 +2042,10 @@ static uint16_t bnxt_parse_eth_link_speed(uint32_t 
conf_link_speed)
                eth_link_speed =
                        HWRM_PORT_PHY_CFG_INPUT_FORCE_LINK_SPEED_50GB;
                break;
+       case ETH_LINK_SPEED_100G:
+               eth_link_speed =
+                       HWRM_PORT_PHY_CFG_INPUT_FORCE_LINK_SPEED_100GB;
+               break;
        default:
                PMD_DRV_LOG(ERR,
                        "Unsupported link speed %d; default to AUTO\n",
@@ -2054,7 +2058,7 @@ static uint16_t bnxt_parse_eth_link_speed(uint32_t 
conf_link_speed)
 #define BNXT_SUPPORTED_SPEEDS (ETH_LINK_SPEED_100M | ETH_LINK_SPEED_100M_HD | \
                ETH_LINK_SPEED_1G | ETH_LINK_SPEED_2_5G | \
                ETH_LINK_SPEED_10G | ETH_LINK_SPEED_20G | ETH_LINK_SPEED_25G | \
-               ETH_LINK_SPEED_40G | ETH_LINK_SPEED_50G)
+               ETH_LINK_SPEED_40G | ETH_LINK_SPEED_50G | ETH_LINK_SPEED_100G)
 
 static int bnxt_valid_link_speed(uint32_t link_speed, uint16_t port_id)
 {
@@ -2118,6 +2122,8 @@ bnxt_parse_eth_link_speed_mask(struct bnxt *bp, uint32_t 
link_speed)
                ret |= HWRM_PORT_PHY_CFG_INPUT_AUTO_LINK_SPEED_MASK_40GB;
        if (link_speed & ETH_LINK_SPEED_50G)
                ret |= HWRM_PORT_PHY_CFG_INPUT_AUTO_LINK_SPEED_MASK_50GB;
+       if (link_speed & ETH_LINK_SPEED_100G)
+               ret |= HWRM_PORT_PHY_CFG_INPUT_AUTO_LINK_SPEED_MASK_100GB;
        return ret;
 }
 
-- 
2.14.3 (Apple Git-98)

Reply via email to